Still deciding? Get samples of $ !
Request Sample
|
| Customization: | Available |
|---|---|
| Theory: | Voltage Relay |
| Usage: | Car Relay, Household Appliances Relay |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency

| Main technical parameters | ||||||||||
| Oral main contact parameters | ||||||||||
| structure | H | turn on the electricity life | 35A / 750V, 25,000 times | |||||||
| contact material | silver alloy | |||||||||
| contact resistance | ≤5mΩ (@20A) | divide power off life | / | |||||||
| rated load | DC750V 60A DC450V 100A DC200V 150A |
mechanical life | 200,000 times | |||||||
| switch electricity life | 40A / 750V, 1,000 times for 60A 40A /450V,1000 times for 100A 150A /200V,1000 times for 150A |
rated current | 60A | |||||||
| 50A / 600V, 2,000 times for 60A 60A /750V,1000 times for 100A 40A /750V,1000 times for 150A |
||||||||||
| 60A / 450V, 3,000 times for 60A 80A /450V,3000 times for 100A 80A /450V,3000 times for 150A |
min load current | 6V/1A | ||||||||
| Port auxiliary contact parameters | ||||||||||
| structure | / | rated load | / | |||||||
| contact resistance | / | switch electricity life | / | |||||||
| coil parameters | ||||||||||
| Rated voltage (Vd.c) | 12 | 24 | starting current (A) | 0.235 | 0.116 | |||||
| input voltage (Vd.c) | ≤9 | ≤18 | Startup time (ms) | / | / | |||||
| operation voltage (Vd.c) | 9~14 | 18-28 | rated current (A) | 0.235 | 0.116 | |||||
| Release voltag (Vd.c) | ≥1 | ≥2 | Startup power (W) | 2.8 | 2.8 | |||||
| Coil Resistance (Q) (1 ± 7%) | 51 | 206 | steady state power (W) | 2.8 | 2.8 | |||||
| Note : " : when the rated voltage | ||||||||||
| Port performance parameters, mouth safety certification | ||||||||||
| Insulation resistance | between coil and contacts | Above the 1,000 MQ | ||||||||
| Between open contacts of same pole | / | |||||||||
| Between main and auxiliary contacts | Above the 1,000 MQ | |||||||||
| Dielectric strength | between coil and contacts | AC4000V/1 Minutes | ||||||||
| Between open contacts of same pole | / | |||||||||
| Between main and auxiliary contacts | AC4000V/1 Minutes | |||||||||
| Shock Resistance | 10kV (1.2*50 μ s) | |||||||||
| operate time | Below the 30ms | |||||||||
| release time | Below the 10ms | |||||||||
| Suction and jump | Below 5ms | |||||||||
| Vibration | sinusoidal vibration | 10-500 Hz double amplitude 1.5mm, acceleration 49 m / s² |
||||||||
| Strike | stability | 196 m/s² | ||||||||
| strength | 490 m/s² | |||||||||
| operating temperature | -40~+85ºC (No ice, no condensation) |
|||||||||
| operating humidity | 5~85%RH | |||||||||
| weight | 12V | About 112g | ||||||||
| 24V | About 112g | |||||||||
| 48V | / | |||||||||